Products

Combustion controls and burner management

Two different jobs that get discussed as one: keeping the boiler safe, and keeping it efficient.

At a glance
Burner management Purge, ignition supervision, flame proving, safety shutdown
Combustion control Firing-rate modulation and air/fuel ratio
Oxygen trim Corrects for air temperature, fuel variation, barometric drift and wear
Sequencing Lead/lag across multiple boilers
Ratio method Single-point positioning, or parallel positioning; fully metered on large plants
Code CSD-1 and applicable NFPA requirements; insurer may exceed both
Integration BAS reporting: specify the protocol up front, not later
Retrofit Constrained by the installed burner; identify it before specifying

Burner management is a safety system governed by code. Its behavior is not a matter of preference.

What it is

The short version

Burner management is the safety system. It proves purge, supervises ignition, watches the flame, and shuts the fuel off when a condition is not satisfied. It is governed by code, and its behavior is not a matter of preference.

Combustion control is the efficiency system: it modulates firing rate against demand and holds the fuel-air ratio across the range. Oxygen trim closes the loop by measuring flue gas and correcting for the things a fixed curve cannot know: air temperature, barometric pressure, fuel variation, and the drift that comes with wear.

Sequencing sits above both, deciding which boiler in a multi-unit plant runs and in what order. On plants with several units this is frequently the cheapest efficiency available, because it costs no new heating surface.

Specifying

What decides the selection

Code and jurisdiction
CSD-1 and the applicable NFPA requirements set the floor for the burner management system, and the insurer may set a higher one. Establish which applies before comparing products. It eliminates options rather than ranking them.
Retrofit or new
Retrofitting controls onto an installed burner is the more common job and the more constrained one. What is already there governs what can be done, so the existing equipment has to be identified before anything is specified.
Oxygen trim payback
Trim earns its keep on units that run long hours at varying load. On a boiler that runs a few hundred hours a year the payback rarely justifies it, and saying so is more useful than selling it.
Integration
Whether the system has to report to a building automation system, and over which protocol. Retrofitting communications later is consistently more expensive than specifying it now.
Who maintains it
A control system nobody on site can service is a liability regardless of its capability. Match the sophistication to the people who will actually be standing in front of it at 2am.
Before we quote

What to send us

Send what you have and we'll tell you what's missing. Knowing this up front is the difference between a quote this week and a quote after three rounds of questions.

Lines for this category announced at launch

We're finalizing manufacturer agreements now. Need something priced before then? We quote today.

Existing equipment
Boiler and burner make and model, and the current control model numbers: photos of the panel and its wiring.
Scope
Burner management, combustion control, oxygen trim, sequencing, or some combination.
Code
The jurisdiction and any insurer requirements that apply.
Plant size
How many boilers, and whether they need to be sequenced together.
Integration
BAS protocol, if the system has to report upstream.
Downtime
What outage window is available. It frequently decides the approach.

Have a spec, or just a nameplate?

Send what you have. We'll come back with selections, pricing, and lead times.

Get it priced